Cable 4020 gives a gateway power on vehicles and machines that have no diagnostic port to plug into. It is a wiring job, so here are the wires, the fuse and the steps.

Cable 4020 lets fleets install a Vehicle Gateway or an Asset Gateway on vehicles without a diagnostic port, such as older or specialized construction and oil and gas equipment, pre-2000 vehicles, bulldozers and golf carts, according to Motive's cable overview. The install article says the guide is only for non-ELD mandate customers. The overview also says the cable powers the Asset Gateway with a waterproof DB-15 connector, a bare wire ground and fuse-protected 12V power.
Cable 4020, 4 zip ties, 6 cable clips, 2 ring terminals, 2 flat terminals, 1 boot and a 5 amp fuse.
Multimeter, wire stripper and crimper, wire brush, electrical tape, and an add-a-circuit or in-line fuse tap.
| Wire | Label | Connect to |
|---|---|---|
| Blue | Power | A 12V to 24V source. A constant source lets the device run on battery when the engine is off. Motive recommends a switched or ignition source if battery drain is a concern. |
| White | Ground | Chassis or battery ground. Motive recommends battery ground. |
Put an in-line 5 amp fuse on the blue power wire. When you install in a fuse box, Motive recommends a fuse tap.
The DB-15 connector goes on the gateway. Remove the plastic washers around the thumbscrews so the cable seats properly, then tighten both thumbscrews.
1. Attach the DB-15 to the gateway, washers off, both thumbscrews tight.
2. Identify the blue power and white ground wires.
3. Find a ground point and use the multimeter to confirm it reads 0V.
4. Connect the white wire there.
5. Choose a switched or constant source that gives 12V to 24V.
6. For a switched source, run the engine or turn on the power switch and confirm 12V to 24V, then turn it off again.
7. Connect the blue wire to the source through the 5 amp in-line fuse.
8. On cable runs, make a drip loop where the cable meets the vehicle to keep water out.
A constant source keeps the gateway alive when the machine is parked, so it can report. It also means the cable draws from the battery all the time. Motive recommends a switched source when battery drain is a concern. A machine that sits for weeks is the case to talk through with the customer before you pick a wire.
Motive's notes cover four things. Take the plastic washers off the DB-15 thumbscrews so the connector seats fully. Tighten both thumbscrews. Prefer the battery ground over a chassis ground. And make a drip loop where the cable meets the vehicle, so water runs off the loop and not into the connection. The 5 amp in-line fuse on the blue wire protects the wire and the device if something shorts, so do not skip it and do not swap in a larger fuse. If you are tapping a fuse box, use the fuse tap Motive recommends and not a splice.
It describes no light patterns, so use the Lights and Sounds page after power-up. Cable length is also not listed.
Blue is power and white is ground.
A 5 amp in-line fuse on the blue power wire.
Motive says the guide is only applicable to non-ELD mandate customers.
Sources: Motive help center, Cable 4020 and Cables overview, read Nov 25, 2026
Tell us how many vehicles you run and what you want to see, and we will match you to the right Motive devices and the install that goes with them.
We Supply It. We Install It. One Call.